Choppers & Prechoppers

38 productos

Mostrando 25 - 38 de 38 productos
Ver
Ahorrar €169
7-069 Phaco Cleaver, LHD, Angled, Length 120 mm, Round Titanium Handle7-069 Phaco Cleaver, LHD, Angled, Length 120 mm, Round Titanium Handle
FINAL SALE
Ahorrar €36.40
7-068 Phaco Cleaver, RHD, Angled, Length 120 mm, Round Titanium Handle7-068 Phaco Cleaver, RHD, Angled, Length 120 mm, Round Titanium Handle
Ahorrar €35.80
7-097 Micro Finger Chopper, Round Handle, Length 120 mm, Round Titanium Handle7-097 Micro Finger Chopper, Round Handle, Length 120 mm, Round Titanium Handle
Ahorrar €44.80
7-127 Chang Chopper, Double-Ended, RHD, Length 125 mm, Round Titanium Handle7-127 Chang Chopper, Double-Ended, RHD, Length 125 mm, Round Titanium Handle
Ahorrar €37.40
7-099 Buratto Manipulator, Length 118 mm, Round Titanium Handle7-099 Buratto Manipulator, Length 118 mm, Round Titanium Handle
Key Design Features
• Fine nucleus splitting tips
• Ergonomic handle geometry
• Varied angles and tip shapes
• Titanium or stainless steel designs
• Designed for intraocular maneuverability
Related procedures
• Phacoemulsification
• Cataract surgery
• Nucleus chopping
• Prechop techniques
• Small-incision cataract surgery
RUMEX Expertise
• Overnight, express and economy shipping options available
• Directly from manufacturer
• Instruments are co-designed with practicing doctors
• CE compliance
• Flexible payment options including PO payments
FAQ
Which chopper design is best for dense nuclei?
A sturdy sharp-tipped chopper with a design suited to horizontal or vertical chopping can improve control in dense nuclei. The best choice depends on the surgeon’s preferred technique.

What is the difference between choppers and prechoppers?
Choppers divide the nucleus during phacoemulsification. Prechoppers mechanically crack or divide the nucleus before or at the start of phacoemulsification, potentially reducing the need for ultrasonic energy.

Are left-handed versions available?
Left- and right-handed versions are available, particularly for angled instruments. RHD models are designed for a Right Hand Dominant Doctor, the chopper is to be held in the non-dominant (left) hand during the surgery. LHD models are for a Left Hand Dominant Doctor, the chopper is to be held in the non-dominant (right) hand during the surgery.

Can these be used through micro-incisions?
Micro-incision versions are available for sub-1.50 mm incision sizes.

How should tips be inspected for wear?
Inspect the tip under magnification for dulling, bending, burrs, cracks, corrosion, or misalignment. Do not use an instrument with damaged or improperly closing jaws.